Welcome to BeaconMedaes
Home >> NFPA Products >> Air >> Instrument Air

Instrument Air

Instrument Air Systems | Instrument Society of America | BeaconMedaes

What is Instrument Air?

Medical Instrument Air is compressed air purified to meet the requirements of the Instrument Society of America and NFPA as an alternative to Nitrogen.  Equivalent to Nitrogen in pressure, dryness, and cleanliness, Instrument Air can support multiple medical applications including driving surgical tools, operating pneumatic brakes and tables, central sterile supply, and laboratory air.

Reducing Operating Costs
Producing high pressure air in-house, an Instrument Air system saves money in multiple ways for your facility.

  • No more Nitrogen gas purchases or monthly cylinder rental fees.
  • Eliminate labor required to change cylinders constantly.
  • Remove the burden of managing the cylinder system.

HMI Touch Screen Display

All BeaconMedæs Instrument Air systems feature full-color HMI touch-screen display panels. Additional features include display screens showing service due warnings, a downloadable alarm and service history log, a system maintenance schedule, and multiple trend graphs for pressure and dew point.

Complete Source for Instrument Air Systems

Let a BeaconMedæs representative analyze your current needs and recommend the best medical support gas application for you. With multiple compressor configurations and necessary pipeline components, BeaconMedæs can save you money right away.

Download PDF of Instrument Air White Paper


Click here to download product documents for Instrument Air

Model
HP
KW
System
System Capacity1
CFM
l/s
SPC (Single Point Connection) Base Mount Systems
HPA-7S-D200
7.5
5.6
Simplex (with Cylinder Backup)
16.5
7.8
HPA-10S-D200
10
7.5
24
11.3
HPA-7D-D200
7.5
5.6
Duplex
16.5
7.8
HPA-10D-D200
10
7.5
24
11.3
HPA-7T-D200
7.5
5.6
Triplex
33
15.6
HPA-10T-D200
10
7.5
48
22.7
HPA-7Q-D200
7.5
5.6
Quadruplex
49.5
23.4
HPA-10Q-D200
10
7.5
72
34.0
Expandable SPC (Single Point Connection) Base Mount Systems
HPA-7D-D200-T
7.5
5.6
Duplex Expandable to Triplex
16.5
7.8
HPA-10D-D200-T
10
7.5
24
11.3
HPA-7T-D200-Q
7.5
5.6
Triplex Expandable to Quadruplex
33
15.6
HPA-10T-D200-Q
10
7.5
48
22.7
1. All capacities are shown as NFPA system capacities (reserve compressor on standby). Unit performance shown in Inlet Cubic Feet per Minute with system losses subtracted from pump capacity. System capacity measured at 200 psig.
2. Normal operating conditions at a maximum ambient of 105°F. Consult factory for higher ambient conditions.


Click Here To View Large Image
BeaconMedaes Instrument Air System